Carrier & Bryant Furnace and Heat Pump LED Flash Codes

How to read the status LED on a Carrier or Bryant furnace or heat pump, what codes 13, 14, 31, 33 and others mean, and which ones you can safely handle yourself.

HVAC Express Service6 min read

Carrier & Bryant Furnace and Heat Pump LED Flash Codes

Carrier and Bryant furnaces and heat pumps report faults by flashing a status LED on the control board. Most furnaces use a two-digit code: count the short flashes for the first digit, then the long flashes for the second. Three short flashes followed by three long ones is code 33. The tables below come from Carrier's own installation and wiring documents. Each one names the equipment it covers, because the code list on your unit's door label is the one that counts.

Bryant is a Carrier brand, and many Bryant furnaces and heat pumps use the same family of controls. Even so, check the service label on the inside of the blower or control-box door before you rely on any table. That label is printed for your exact model.

Reading the furnace status LED

Carrier's 58SB0A/58SB1A furnace manual describes three LED states. The light can be on continuously, rapid flashing, or flashing a two-digit code. You can see it through the sight glass in the blower access door, so you don't need to remove anything.

  • Rapid flashing means the 115-volt polarity is wrong, and the furnace will not operate. That's a wiring problem for an electrician or HVAC technician.
  • Write the code down before you cut power. On controls with a red LED, stored codes are erased when 115V or 24V power is interrupted. Turning the furnace off at the switch can wipe out the most useful clue.

Furnace status codes (Carrier 58SB0A / 58SB1A, single-stage 80% gas furnace)

CodeWhat it meansWhat you can safely checkWhen to call
11No previous code. Stored codes clear after 72 hoursNothing; no stored fault—
12Blower on after power-up. Normal: the blower runs 90 seconds if power is restored during a call for heatNothing—
13Limit circuit lockout: a limit, draft safeguard, flame rollout or blocked-vent switch was open longer than 3 minutes. Auto-resets after 3 hoursReplace a dirty filter; open closed supply registersAlways find out why a limit opened. Rollout switches need a technician
14Ignition lockout: failed to light and prove flame in 4 attempts. Auto-resets after 3 hoursMake sure the furnace's gas shut-off valve is onIf it locks out again
21Gas heating lockoutNothing user-serviceableControl relay or gas valve wiring
22Abnormal flame-proving signal: flame sensed while the gas valve is off. The inducer keeps runningNothing user-serviceableRight away. Stuck-open or leaky gas valve
23Pressure switch did not openNothing user-serviceablePressure tube or switch
24Secondary (24V) fuse open: short in the low-voltage wiring, including thermostat wiresNothing user-serviceableFind the short before the fuse is replaced
31Pressure switch didn't close, or reopenedFrom outside, check that the vent and intake pipes aren't blocked by snow or debrisInducer, pressure switch, venting or combustion air
33Limit circuit fault: limit, draft safeguard, flame rollout or blocked-vent switch openReplace a dirty filter; open supply registersIf it repeats or turns into 13
34Ignition proving failure: flame not sensed during trial for ignitionConfirm the furnace's gas shut-off valve is onFlame sensor, igniter or gas valve diagnosis
45Control circuitry lockout. Auto-resets after 1 hourReset power once, per the manualIf it repeats, the control board needs replacing

Carrier's troubleshooting guide lists a dirty filter or restricted duct system first among the causes of code 33. Changing the filter really is the first thing to try. The flame rollout switch and blocked-vent shutoff switch need a manual reset, and a tripped rollout switch is a warning about combustion or venting. Don't keep resetting it. Have it diagnosed.

Heat pump status codes (Carrier 25HPA6 Performance two-stage heat pump)

The outdoor control board on the 25HPA6 uses the same short-then-long flash scheme. These codes come from the wiring diagram Carrier prints for the unit.

CodeWhat it meansWhat you can safely checkWhen to call
On, no flashStandby——
1, pauseRunning low stage——
2, pauseRunning high stage——
16System communications failureCheck the thermostat has powerIf it persists
25Invalid model plugNothing user-serviceableControl configuration
31High-pressure switch or discharge temperature switch tripClear leaves, snow and debris from the outdoor coil; replace the indoor filterIf it repeats
32Low-pressure switch tripReplace the indoor filterRefrigerant or airflow diagnosis
45Control faultNothing user-serviceableBoard diagnosis
46Brownout (230V)Note any building power issuesIf it repeats
47No 230V with a call to runCheck the outdoor disconnect and the breakerIf power is on and the code remains
53Outdoor air temperature sensor faultNothing user-serviceableSensor replacement
55Coil temperature sensor faultNothing user-serviceableSensor replacement
71 / 72Low / high stage thermal cutoutNothing user-serviceableCompressor diagnosis
73Contactor shortedNothing user-serviceableContactor replacement
74Contactor open (no 230V to compressor)Nothing user-serviceableContactor or wiring
81 / 82Low / high stage thermal lockout (4 hours)Nothing user-serviceableCompressor diagnosis
83Low-pressure lockout (4 hours)Nothing user-serviceableRefrigerant diagnosis by an EPA-certified technician
84High-pressure lockout (4 hours)Clear the outdoor coilFan, coil or refrigerant diagnosis

The same board has a five-minute short-cycle protector. After the outdoor unit shuts off, there's a built-in delay before the compressor restarts. A heat pump that sits idle for a few minutes after you change the thermostat isn't broken.

What's safe to try

  1. Read and record the code first. Look through the sight glass, count the flashes twice to be sure, and write the code down before you touch any switch.
  2. Replace the furnace filter. It's the most common cause of limit codes 13 and 33, and of the pressure trips on a heat pump.
  3. Check the gas shut-off valve and the breakers. Make sure the furnace's gas valve handle is on and the furnace switch and breaker are on. For the heat pump, make sure the outdoor disconnect and breaker are on.
  4. Look at the vents and the outdoor unit. Clear snow from high-efficiency vent and intake pipes, and clear debris from around the heat pump. Look, don't take anything apart.
  5. Allow the automatic reset. Furnace codes 13 and 14 reset on their own after 3 hours, and 45 after 1 hour. Repeatedly cycling power to get around a lockout hides the real problem.

If you smell gas, don't touch any switch. Leave the building and call your gas utility or 911 from outside. Never bypass a limit, rollout or pressure switch, never open the gas valve or burner compartment, and leave refrigerant work to EPA-certified technicians.

When to call a technician

  • Code 22 (flame sensed with the gas valve off). Call right away.
  • Any lockout that comes back after the automatic reset (13, 14, 45, heat pump 81–84).
  • Code 24. A blown low-voltage fuse means there's a short somewhere, and a new fuse will just blow again.
  • Repeated 31, 33 or 34 on a furnace with a clean filter.
  • Any heat pump code that points to a sensor, the contactor, the compressor or refrigerant pressure.

When you call, have the model number from the rating plate and the exact flash code ready.

Our independent, EPA-certified technicians work on Carrier and Bryant equipment across Manhattan and the other four boroughs. We offer 24/7 emergency service for no-heat calls and give you upfront pricing before work starts. See Carrier central AC and heat pump repair and heating system installation, or request service with your code.